No 4 Metal Black EPDM

27.00
No 4 Metal Black EPDM 76-152mm 250x250 APPLICATION Suitable for profiled sheeting and flat panel surfaces and is temperature resistance -55°C to 135°C. CONSTRUCTION Made of EPDM, these flashings are compounded specifically for maximum resistance to weathering due to ozone and ultraviolet light. The one piece construction allows for quick and easy on-site installation - usually taking no longer than five minutes. The base is designed to form a seal on most panel configurations and roof pitches regardless of pipe location. INSTALLATION 1. Choose pipe opening and trim using a stanley knife or scissors. 2. Slide flashing over pipe (you may need to lubricate the flashing with some grease). 3. Form the flashing to the same profile as the roof. 4. Apply sealant (contained in the Fixing Kit). 5. Fasten using the screws and caps (supplied in the Fixing Kit). ONE Standard Fixing Kit is required to install this flashing.

No 4 Metal Grey SILICONE

41.50
No 4 Metal Grey SILICONE 76-152mm 250x250 APPLICATION Suitable for profiled sheeting and flat panel surfaces and is temperature resistance -74°C to 260°C CONSTRUCTION Made of SILICONE, these flashings are compounded specifically for maximum resistance to weathering due to ozone and ultraviolet light. The one piece construction allows for quick and easy on-site installation - usually taking no longer than five minutes. The base is designed to form a seal on most panel configurations and roof pitches regardless of pipe location. INSTALLATION 1. Choose pipe opening and trim using a stanley knife or scissors. 2. Slide flashing over pipe (you may need to lubricate the flashing with some grease). 3. Form the flashing to the same profile as the roof. 4. Apply sealant (contained in the Fixing Kit). 5. Fasten using the screws and caps (supplied in the Fixing Kit). ONE Standard Fixing Kit is required to install this flashing.

Size 1 High Temp Grey SILICONE Size 80-200mm

80.00
Suitable for tiled or slate roofs with external pipe diameters of 80mm to 200mm The aluminium base size is 605mm x 505mm, suitable for high temperatures APPLICATION Suitable for tiled roofs and is temperature resistance -74°C to 260°C CONSTRUCTION Enviromentally safe lead free aluminium base. The SILICONE rubber upstand has a 20 year life. The built in 20° pitch allows adaptability to almost any roof pitch including 45°. The pull tab design and easy smooth tear grooving is intended to eliminate cutting by knife and allow for a circular hole. INSTALLATION 1. Pull tab design to correct size using pliers, alternatively cut using a stanley knife. 2. Apply silicone sealant to back of flashing. 3. Remove tiles around pipe and slide flashing over pipe. 4. Fasten Flashing to the roof. 5. Cut tile to fit to the top of the Flashing allowing the bottom of the flashing metal base to sit on top of the tiles.

Size 1 Low Temp Black EPDM Size 80-200mm

38.00
Suitable for tiled or slate roofs with external pipe diameters of 80mm to 200mm The aluminium base size is 605mm x 505mm, suitable for low temperatures APPLICATION Suitable for tiled roofs and is temperature resistance -55°C to 135°C CONSTRUCTION Enviromentally safe lead free aluminium base. The EPDM rubber upstand has a 20 year life. The built in 20° pitch allows adaptability to almost any roof pitch including 45°. The pull tab design and easy smooth tear grooving is intended to eliminate cutting by knife and allow for a circular hole. INSTALLATION 1. Pull tab design to correct size using pliers, alternatively cut using a stanley knife. 2. Apply silicone sealant to back of flashing. 3. Remove tiles around pipe and slide flashing over pipe. 4. Fasten Flashing to the roof. 5. Cut tile to fit to the top of the Flashing allowing the bottom of the flashing metal base to sit on top of the tiles.

Size 1 Low Temp Black EPDM Size 80-200mm Lead Base

138.00
Suitable for tiled or slate roofs with external pipe diameters of 80mm to 200mm The lead base size is 605mm x 505mm, suitable for low temperatures APPLICATION Suitable for tiled roofs and is temperature resistance -55°C to 135°C CONSTRUCTION Enviromentally safe lead free aluminium base. The EPDM rubber upstand has a 20 year life. The built in 20° pitch allows adaptability to almost any roof pitch including 45°. The pull tab design and easy smooth tear grooving is intended to eliminate cutting by knife and allow for a circular hole. INSTALLATION 1. Pull tab design to correct size using pliers, alternatively cut using a stanley knife. 2. Apply silicone sealant to back of flashing. 3. Remove tiles around pipe and slide flashing over pipe. 4. Fasten Flashing to the roof. 5. Cut tile to fit to the top of the Flashing allowing the bottom of the flashing metal base to sit on top of the tiles.

Standard Fixing Kit

19.50
One Kit is required for No.3, No.4, No.5, No,6... Two Kits required for No.7, No.8 ... Three Kits for No.9... Four Required for Maxi Contents. 8 x 5mm Self Tapping Screws with Washers and Screw Caps. 1 x 5mm Drill Bit. 1 x 80ml Tube Clear Silicone Sealant.

Storm Collar – Ø 80

20.00
Used to ensure water tightness in the passage through the roof. It also protects the flashing from extreme weather conditions. Its should be installed about 25mm above the tallest part of the flashing ConvesaTWPro Fit System Super easy assembly, It takes one second and the one hand to put two parts together including attaching the locking band! The wall bands are embedded in to the pipe itself, so no protrusions between one section to the next. APPLICATION For use on solid fuel and gas/oil appliances. eg: Pellet Stoves, woodstoves, gas coal effect fires, oil and gas boiler and any solid fuel appliances.